Water pressure drop |
Water pressure drop-=-Cooling-=-kPa |
kPa |
29 (4) |
|
Water pressure drop-=-Heating-=-kPa |
kPa |
23 (4) |
Control systems |
Control systems-=-Wired remote control |
FWEC3A |
Water flow |
Water flow-=-Heating-=-l/h |
l/h |
853 (4) |
|
Water flow-=-Cooling-=-l/h |
l/h |
853 (4) |
Fan motor |
Fan motor-=-Model |
|
Μόνιμος μαγνητικός ρότορας, μόνωση κλάσης F, προστασία ηλεκτρονικής υπερφόρτωσης |
Cooling capacity |
Cooling capacity-=-Total capacity |
Cooling capacity-=-Total capacity-=-Min.-=-kW |
kW |
0.88 (1) |
|
|
Cooling capacity-=-Total capacity-=-Max.-=-kW |
kW |
4.96 (1) |
|
Cooling capacity-=-Sensible capacity |
Cooling capacity-=-Sensible capacity-=-Min.-=-kW |
kW |
0.58 (1) |
|
|
Cooling capacity-=-Sensible capacity-=-Max.-=-kW |
kW |
3.60 (1) |
Heat exchanger |
Heat exchanger-=-Water volume-=-l |
l |
1 |
|
Heat exchanger-=-Fin pitch-=-mm |
mm |
1.6 |
|
Heat exchanger-=-Stages |
Heat exchanger-=-Stages-=-Quantity |
10 |
|
Heat exchanger-=-Rows |
Heat exchanger-=-Rows-=-Quantity |
3 |
|
Heat exchanger-=-Face area-=-m² |
m² |
0.138 |
Piping connections |
Piping connections-=-Drain |
Piping connections-=-Drain-=-OD-=-mm |
mm |
16 |
|
Piping connections-=-Water |
Piping connections-=-Water-=-Outlet |
1/2" |
|
|
|
Piping connections-=-Water-=-Inlet |
1/2" |
Power input |
Power input-=-Min.-=-W |
W |
2.2 |
|
Power input-=-Max.-=-W |
W |
82.7 |
Sound power level |
Sound power level-=-Max.-=-dBA |
dBA |
70 |
|
Sound power level-=-Min.-=-dBA |
dBA |
28 |
Air filter |
Air filter-=-Type |
|
Πλαστικό |
Dimensions |
Dimensions-=-Unit |
Dimensions-=-Unit-=-Width-=-mm |
mm |
987 |
|
|
Dimensions-=-Unit-=-Depth-=-mm |
mm |
226 |
|
|
Dimensions-=-Unit-=-Height-=-mm |
mm |
564 |
Casing |
Casing-=-Colour |
|
Πλαστικό και μεταλλικό RAL9010 |
|
Casing-=-Material |
|
Πλαστικό + γαλβανισμένο μέταλλο |
Weight |
Weight-=-Unit-=-kg |
kg |
25 |
Fan |
Fan-=-Air flow rate |
Fan-=-Air flow rate-=-Max.-=-m³/h |
m³/h |
900 (3) |
|
|
Fan-=-Air flow rate-=-Min.-=-m³/h |
m³/h |
95 (3) |
|
Fan-=-Quantity |
|
2 |
|
Fan-=-Type |
|
Φυγοκεντρικός, πολλαπλών πτερυγίων, διπλής αναρρόφησης |
Heating capacity |
Heating capacity-=-2-Pipe |
Heating capacity-=-2-Pipe-=-Max.-=-kW |
kW |
6.40 (2) |
|
|
Heating capacity-=-2-Pipe-=-Min.-=-kW |
kW |
0.95 (2) |
Vibration insulation |
|
|
Ελαστικός δακτύλιος για κινητήρα ανεμιστήρα |
Insulation material |
|
|
Αυτοσβενόμενο, Κατηγορία 1 |
Template |
|
|
|
FCU |
Current input |
Current input-=-Min.-=-A |
A |
0.05 |
|
Current input-=-Max.-=-A |
A |
0.72 |
Required wire section-=-mm² |
mm² |
|
|
1 |
Required fuses-=-A |
A |
|
|
1 |
Power supply |
Power supply-=-Frequency-=-Hz |
Hz |
50 |
|
Power supply-=-Voltage-=-V |
V |
230 |
|
Power supply-=-Phase |
1~ |
Ψύξη: 2 σωλήνες: αέρας 27°CDB, 19°CWB, νερό εισόδου 7°C, νερό αναχώρησης 12°C |
Θέρμανση: 2 σωλήνες: αέρας 20°CDB, νερό προσαγωγής 50°C, ταχύτητα ροής νερού ίδια με αυτήν κατά την ψύξη |
Ροή αέρα σε 0Pa ESP |
|
|
Οι τιμές ταχύτητας ροής νερού και πτώσης πίεσης νερού είναι σε μέγιστη ταχύτητα |
Η κατανάλωση ρεύματος για τη μηχανική βαλβίδα είναι 5W (κορυφής). Αυτό γίνεται μόνο κατά το άνοιγμα. |